ELSpe-2 PreCon Automated Trace Metals Preconcentration and Matrix Removal System

ELSpe-2 PreCon automated trace metals preconcentration and matrix removal system is a sample preparation system for complex samples such as seawater, alkali metal salts, alkaline earth metal salts, acid and base reagents, etc. It utilizes the different retention characteristics of the chelate column for different metals to retain and enrich the transition metals and rare earth elements passing through the chelate column while eluting the salt matrix.

ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System
ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System
ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System
ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System
ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System
Get A Guote
Get A Guote

Features of ELSpe-2 PreCon Automated Trace Metals Preconcentration and Matrix Removal System

01.
Ultra-High Sensitivity & Ultra-Fast Analysis

The high-efficiency sample removal system eliminates matrix interference, significantly enhancing signal-to-noise ratios and detection limits. With a 400μL injection volume, the signal-to-noise ratio for 0.1ppb Cd exceeds 1000, with detection limits below 1ppt and an analysis time of less than 3 minutes.

02.
Extreme Desalting Performance

The system excels in handling high-salinity marine samples, where transition metal and heavy metal environmental concentrations are typically at the ng/L level and the salt matrix content is approximately 3.5%. The ELSpe-2 PreCon fully automatic seawater desalting and concentration system removes over 99.9% of the salt content, drastically simplifying seawater sample analysis.

03.
Versatile Analysis Modes

The system supports multiple flexible and swappable analysis modes, including desalting/enrichment (pre-concentration) analysis, automatic dilution analysis, and speciation analysis, as well as hydride generation mode to adapt to various testing requirements.

04.
High Compatibility

The ELSpe-2 Prin-Can system can be seamlessly integrated with ICP-MS systems from all major brands, ensuring broad applicability in advanced analytical laboratories.

Specifications of ELSpe-2 PreCon Automated Trace Metals Preconcentration  and Matrix Removal System


ModelELspe-2 PreCon
Application areas and Standards methods followedComplies with USEPA200.10 "Determination of Trace Elements in Marine Waters by On-Line Chelation Preconcentration and Inductively Coupled Plasma - Mass Spectrometry".
Detection Limitppt level
Flow Rate Range0.01~5.00 mL/min
Flow Accuracy<0.1%
Pressure Range0~5000 psi (35 MPa)
Pressure Pulsation<0.1%
Analyze Time3 mins
Analysis MethodChelation chromatography - ICPMS
SoftwareEasySpec Workstation provides instrument control and data acquisition/storage/processing, supporting chromatographic peak integration, qualitative analysis by retention time, peak area/concentration calculations, half-peak width calculation, and signal-to-noise ratio calculation.
Power Supply220V±10%, 50Hz
Instrument DimensionsBenchtop, modular stacking, 470mm440mm735mm (LWH)
Instrument Weight52kg



Get in Touch with Prin-Cen
Got questions regarding our ion chromatography instruments or technical solutions? Reach out to our professional team—we’ll deliver expert customized solutions in a timely manner.
E-mail
sales@princensci.com
Call Us
+86 20 82510732
Address
Room 108, Block 3, No.31, Nanxiang Er Road, Huangpu District, Guangzhou, Guangdong Province, China
Contact Us
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy
Reject All
Accept All