Prin-Cen’s IC columns include conventional ion chromatography columns, speciation analysis columns, and enrichment columns, with specifications such as 4.0 × 50 mm and 3.0 × 50 mm. Designed for high separation efficiency, rapid analysis, and broad compatibility, they support carbonate, hydroxide, and methanesulfonic acid eluent systems for the fast separation of anions, cations, hexavalent chromium, and arsenic species. Suitable for environmental, food, toy, and marine testing, these columns serve as core separation components for accurate and reliable ion chromatography analysis.

Types of IC Ion Chromatography Columns

PAS-19  IC Column
PAS-19 IC Column
The PAS-19 IC column is suitable for industries such as food, environmental protection, metallurgy, and geology, and is used to separate and quantify common anions, disinfection by-products, and organic acids.
PAS-22  IC Column
PAS-22 IC Column
The PAS-22 IC column is suitable for industries such as environmental protection, food, geology, and consumer products, and is used to separate and quantify common anions and iodide ions.
PAS-23 IC Column
PAS-23 IC Column
The PAS-23 IC column is suitable for industries such as environmental protection, food, geology, and consumer products, and is used to separate and quantify common anions, disinfection by-products, and organic acids.
PCG-1  IC Column
PCG-1 IC Column
The PCG-1 IC column is suitable for industries such as environmental protection, metallurgy, and geology, and is used to separate and quantify common cations.
PCS-1 IC Column
PCS-1 IC Column
The PCS-1 IC column is suitable for industries such as environmental protection, metallurgy, and geology, and is used to separate and quantify common cations.
OWT104  Cr(VI) Analysis  Water Only Kit
OWT104 Cr(VI) Analysis Water Only Kit
The OWT104 Cr(VI) Analysis Water Only Kit is designed for hexavalent chromium determination in soil, solid waste, water, toys, leather, and food.
OWT105 Water Only Analysis Column
OWT105 Water Only Analysis Column
The OWT105 Water Only Analysis Column is designed for hexavalent chromium (Cr(VI)) analysis and detection in water samples.
OWT106 Water Only Analysis Column
OWT106 Water Only Analysis Column
The OWT106 Water Only Analysis Column is designed for hexavalent chromium (Cr(VI)) analysis and detection in water samples.

How IC Columns Ensure Consistent Performance in Complex Sample Matrices

Prin-Cen’s IC Columns adopt high-quality packing and precise preparation technology, with excellent anti-interference ability for complex matrices such as high-salt seawater and industrial wastewater. Special columns like hexavalent chromium analysis column and arsenic speciation column realize rapid baseline separation of target substances, and conventional columns ensure stable separation of anions/cations with low peak distortion, maintaining consistent and reliable performance in various complex sample analysis.

IC Column Compatibility and Instrument Configuration

Prin-Cen ion chromatography columns are designed for use with Prin-Cen IC systems and selected verified configurations. Compatibility depends on the column type, eluent, detector, suppression mode, and connection specifications.


Configuration ItemCompatibility Information
Prin-Cen IC SystemsIC-10, IC-20, IC-50
Eluent SystemsCarbonate or hydroxide for anion columns; methanesulfonic acid for cation columns
Detection OptionsConductivity, UV or other verified detectors
Suppression ModeSuppressed or non-suppressed, depending on column
Connection RequirementsTubing, fittings and connector specifications
Recommended Guard ColumnMatch according to analytical column and sample matrix
Third-Party SystemsContact Prin-Cen to confirm compatibility


Ion Chromatography Column Selection by Sample Matrix and Application

The application of column chromatography in ion analysis depends on the target analytes, sample matrix, eluent system and required detection limit.The guide below outlines typical Prin-Cen column options for common applications.


Drinking Water Analysis


Prin-Cen IC columns support the determination of common anions, selected disinfection by-products, organic acids, and common cations in drinking water. PAS-19 is suitable for conventional anion analysis, while PAS-23 also supports selected disinfection by-products and organic acids. PCG-1 and PCS-1 are used for common cation analysis with methanesulfonic acid eluents.


Seawater and High-Salt Samples


High salt concentrations can interfere with trace-level analysis. Prin-Cen OWT401 and OWT402 are suitable for high-salinity water matrices such as open-ocean, nearshore, and estuarine water, supporting trace metal enrichment and solution purification.


Food and Beverage Testing


Food and beverage analysis may involve common inorganic anions, iodide, organic acids, and hexavalent chromium. PAS-19 and PAS-23 support common anion and organic acid analysis, while PAS-22 is suitable for conventional anions and iodide. OWT104 supports hexavalent chromium determination


Environmental and Wastewater Analysis


Environmental and industrial wastewater samples may contain conventional anions, cations, organic acids, and regulated metal species. PAS-19 and PAS-23 support routine anion analysis, PCG-1 and PCS-1 are suitable for common cations, and the OWT104/105/106 series supports hexavalent chromium analysis. Final column selection should be confirmed according to the matrix composition and analytical method.


Consumer Products, Toys and Leather


OWT104 supports hexavalent chromium determination in toys, leather, and other consumer products. PAS-22 is suitable for conventional anions and iodide, while PAS-23 supports conventional anion and organic acid analysis


Geological and Metallurgical Samples


Geological and metallurgical samples may require separate determination of anions and cations after appropriate sample preparation. PAS series columns support anion analysis, while PCG-1 and PCS-1 are designed for common cations. The final configuration can be selected according to the target ions, concentration range, and eluent system.

FAQs about IC Columns

Can Prin-Cen’s IC Columns be used for high-salt matrix sample analysis? Can Prin-Cen’s IC Columns be used for high-salt matrix sample analysis?

Yes. Prin-Cen’s OWT401/402 enrichment and capture IC columns are designed for high-salinity samples such as seawater, supporting desalting, enrichment, and trace metal analysis.

What types of Prin-Cen’s IC Columns are available for conventional ion analysis? What types of Prin-Cen’s IC Columns are available for conventional ion analysis?

Prin-Cen provides ion chromatography columns for both anion and cation analysis. Options include an anion exchange chromatography column for efficient separation of common inorganic anions.

Can Prin-Cen’s IC Columns be used for hexavalent chromium analysis? Can Prin-Cen’s IC Columns be used for hexavalent chromium analysis?

Yes. Dedicated IC columns are available for the separation and determination of hexavalent chromium in water, environmental, and industrial samples.

How fast can Prin-Cen’s arsenic speciation IC Column separate arsenic species? How fast can Prin-Cen’s arsenic speciation IC Column separate arsenic species?

The column is designed for rapid column chromatography separation of different arsenic species. Actual analysis and retention times depend on the eluent, flow rate, and instrument conditions.

What systems are Prin-Cen’s IC Columns compatible with? What systems are Prin-Cen’s IC Columns compatible with?

These ion chromatography columns support carbonate, hydroxide, and methanesulfonic acid eluent systems and can be integrated with compatible column chromatography instrumentation.

What is the specification of Prin-Cen’s fast arsenic speciation IC Column? What is the specification of Prin-Cen’s fast arsenic speciation IC Column?

Prin-Cen’s OWT210 fast arsenic speciation IC Column has a specification of 4.0*50mm, with fast analysis speed and high separation efficiency.

Are Prin-Cen’s IC Columns suitable for drinking water quality detection? Are Prin-Cen’s IC Columns suitable for drinking water quality detection?

Yes. The columns support accurate ion column chromatography for monitoring common anions, cations, hexavalent chromium, and other target substances in drinking water.

Do Prin-Cen’s IC Columns match the company’s ion chromatograph series? Do Prin-Cen’s IC Columns match the company’s ion chromatograph series?

Yes. Prin-Cen’s columns are developed to work with its ion chromatograph series. A suitable guard column in ion chromatography can also be selected to protect the analytical column and improve method stability.

Get in Touch with Prin-Cen
Got questions regarding our ion chromatography instruments or technical solutions? Reach out to our professional team—we’ll deliver expert customized solutions in a timely manner.
E-mail
sales@princensci.com
Call Us
+86 138 0277 0795
Address
Room 108, Block 3, No.31, Nanxiang Er Road, Huangpu District, Guangzhou, Guangdong Province, China
Contact Us
We use cookies to optimise and personalise your experience, but you can choose to opt out of non-essential cookies.
To find out more, read our Privacy Policy
Reject All
Accept All